Home > Product > Heat Shrink Cable Accessories > 35kV Three Core Heat Shrink Outdoor Terminal

    35kV Three Core Heat Shrink Outdoor Terminal

    Provide a full range of 10KV/20KV/35KV heat shrink terminals and intermediate joints (models HSY-35-3.1 to 3.3), suitable for cable cross-sections of 50-400mm ², in compliance with GB11033 standard, with a radial shrinkage rate of ≥ 50%, temperature resistance of -55 ℃~105 ℃, and a 20-year aging life. Through hydrogen sulfide resistance, explosion-proof (ISO 80079-36), and salt spray testing,
  • Category:
    Heat Shrink Cable Accessories
  • Browse number:
    131
  • Release time:
    2024-10-21 17:10:09
  • Share:
  • INQUIRY
voltageproduct namespecificationsmodelCable cross-section(mm)
grade
35KVHeat shrink indoor Terminal1#HSY-35-3.150-90
2#HSY-35-3.2120-185
3#HSY-35-3.3240-400
Heat shrink outdoor terminal1#HSY-35-3.150-90
2#HSY-35-3.2120-185
3#HSY-35-3.3240-400
Heat shrink intermediate joint1#HSY-35-3.150-90
2#HSY-35-3.2120-185
3#HSY-35-3.3240-400


Heat shrink power cable terminal heads and intermediate joint series products for 10KV 20KV and35KV applications, integrating waterproofing, stress control, and insulation. They have good electrical and mechanical performance, and can be used for a long time in various harsh environmental conditions. They have the advantages of light weight and easy installation. They are widely used in the fields of electricity, petrochemicals, metallurgy, railways, ports, and construction.


Heat shrink cable accessories, commonly known as heat shrink cable heads, are widely used for intermediate connections and terminations of cross-linked cables or oil immersed cables with voltage levels below 35KV. Compared with traditional cable accessories, they have the characteristics of small size, light weight, safety and reliability, and easy installation. The product complies with GB11033 standard, with a long-term use temperature range of -55 ℃ to 105 ℃, an aging life of up to 20 years, a radial shrinkage rate of ≥ 50%, a longitudinal shrinkage rate of<5%, and a shrinkage temperature of 110 ℃ to 140 ℃.


The materials used are generally blends of various material components such as polyethylene, ethylene vinyl acetate (EVA), and ethylene propylene rubber.

This type of product mainly uses stress tubes to deal with the problem of electrical stress concentration. Namely, they uses the parameter control method to alleviate stress concentration in the electric field.

The main advantages are light weight, easy installation, good performance and low cost.


Stress tube is a type of heat shrinkable tube with moderate volume resistivity (1010-1012 Ω? cm) and high dielectric constant (20-25). It uses electrical parameters to force the stress at the insulation shielding fracture of the cable to disperse into a more uniform distribution along the stress tube. This technology can only be used in cable accessories of 35kV and below. Because when the voltage level is high, the stress tube will generate heat and cannot work.


The key technical issue in its use is to ensure that the electrical parameters of the stress tube must meet the specified values in the above standards before it can work. Additionally, it is important to use silicone grease to fill the air gap at the break of the cable insulation semiconductor layer to eliminate gas and reduce partial discharge. Cross linked cables may experience significant shrinkage during operation due to poor internal stress treatment. Therefore, when installing accessories, it is important to ensure that the stress tube and insulation shield overlap by no less than 20mm to prevent detachment during shrinkage.


Due to their low elasticity, heat shrinkable attachments may cause air gaps at the interface during thermal expansion and contraction during operation. Therefore, sealing technology is important to prevent moisture from entering.


Key Features and Applications

 

- Excellent All-Weather Performance: The terminal heads are made from advanced radiation cross-linked polymer materials, offering outstanding resistance to UV rays, pollution, moisture, and corrosion, making them suitable for coastal, desert, and industrial areas.

- Reliable Stress Control and Sealing: They feature a built-in stress control layer to effectively smooth out electric field distribution and prevent excessive concentration. During installation, hot-melt adhesive melts to fill gaps, creating a robust waterproof and dustproof seal.

- Dual Ground Wire Process: Many products adopt a design where the steel armor ground wire and copper shield ground wire are separated, making the cable structure more reasonable and operation more reliable.

- Wide Range of Applications: They are widely used in outdoor environments in power, petrochemical, metallurgy, railway, and construction industries.


Installation and Procurement Guide

 

- Installation Overview: Installation requires specialized tools like a gas torch. Key steps include cable preparation, ground wire installation, stress control tube and insulating tube installation, and sealing. It is crucial to avoid overheating and ensure the tubes shrink evenly without carbonization.

- Post-Installation Checks: After installation, ensure the heat-shrink tubes are smooth, free of bubbles, and fully sealed, and verify the ground connection is reliable.

- Points for Procurement: When selecting a product, confirm the model specification matches your cable's voltage level and conductor cross-sectional area.

 

I hope this information helps you better understand the 35kV three-core heat shrink outdoor terminal. If you have more detailed requirements,feel free to let me know, and I can provide further assistance.


Comment

(0)
*Captcha:

ONLINE MESSAGE

*Subject:
*E-mail:
Phone:
Address:
*Captcha:

RELATED PRODUCTS

Follow us:

Oil&Gas exploited

Automotive Manufacturing

Transportation & Dlistrlbutlon

Manufacture

Industrial Construction

Green Energy

About US

Contact US

The news

Terms & conditions

Case Studies

Site map

Copyright ? 2024  All Rights Reserved

Back to top